Use and Care Manual

4.5 Spark Plug (Fig. 5)
Clean or replace spark plug as needed to ensure proper operation. Refer to the engine
owner's manual.
The muler becomes very hot during operation and remains hot for a while aer stop-
ping the engine. Do not touch the muler while it is hot.
Note: Refer to the Technical Data for the recommended spark plug type and the
electrode gap setting (page 6).
To change fluid:
4.4.1 Remove beltguard, belt, and hose from water tank.
4.4.2 Remove four screws (b) securing console assembly to baseplate and li console
assembly from baseplate.
b
73 Nm
(54 .lbs)
30 Nm
(22 .lbs)
c
a
Fig. 4
4.4.3 Remove end cover (c) from bear-
ing exciter assembly. Outer bearing race
will remain with cover.
4.4.4 Tip baseplate up and drain fluid
from exciter assembly. Dispose of used
fluid in an appropriate manner. Contact
local recycling center.
4.4.5 Add 150 ml (5 ounces) of automat-
ic transmission fluid to exciter housing
and fasten end cover to exciter. Do not
overfill exciter or bearings may over-
heat.
4.4.6 Set up console assembly to base-
plate and install belt, beltguard, and
hose to water tank.
13