Safety Data Sheet

Reference Number : MSDS-160308-01
Page 3 of 7
A battery cell and internal cell materials of an opened battery cell
・ Ingestion :
Induce vomiting. When it is impossible or the feeling is not well after vomiting, seek medical attention.
ECTION 5 FIRE-FIGHTING MEASURE
Suitable extinguishing media : Pouring water, carbon dioxide gas, nitrogen gas, chemical powder fire
extinguishing medium and fire foam.
Specific hazards : Corrosive gas may be emitted during fire.
Specific methods of fire-fighting : When the battery burns with other combustibles simultaneously,
take fire extinguishing method which correspond to the combustibles. Extinguish a fire from the
windward as much as possible.
Special protective equipment for firefighters :
Respiratory protection : Respiratory equipment of a gas cylinder style or protection-against-dust
mask
Hand protection : Protective gloves
Eye protection : Goggle or protective glasses designed to protect against liquid splashes
Skin and body protection : Protective cloth
SECTION 6 ACCIDENTAL RELEASE MEASURES
Internal cell materials, such as electrolyte leaked from battery cell, are carefully dealt with according to the
followings.
Personal precautions :
Remove leaked materials with protective equipment (protective glasses and protective gloves). Do not
inhale the gas as much as possible. Moreover, avoid touching with as much as possible.
Environmental precautions : Do not throw out into the environment.
Method of cleaning up : The leaked solid is moved to a container. The leaked place is wiped off with dry
cloth.
Prevention of secondary hazards : Avoid re-scattering. Do not bring the collected materials close to
fire.
SECTION 7 PERCAUTIONS FOR SAFE HANDLING AND USE
Storage
:
Store in a cool, well-ventilated area. Do not expose to high temperature(60
℃).