Owner manual

969 Horsham Road
l
Horsham, Pennsylvania 19044 USA
l
Phone: 215-675-2053 Fax: 215-675-7543
l
info@tonercable.com
Display 2.8”TFT400x240fullcolor
Weight 1.12lb(510g)
Dimensions 6.9x3.9x2in/175x100x52mm(HxWxD)
ACAdaptor Input:100240V~5060HzOutput:12VDC,2A
Battery LiIonsmartbattery(7.2VDC,2300mAh)
OperatingTime >5hours
OperatingTemperature 23ºFto104ºF(5ºCto45ºC)
StorageTemperature ‐4ºFto158ºF(20ºCto70ºC)
Humidity 5%to95%noncondensing
Ruggedness Survives1m(3ft)droptoconcreteonallsides
Interfaces USB2.0,RJ4510/100TEthernetinterfaceforRemoteControl,
Storage 400MB(internal)formeasurements
Poweruptime <10seconds
FrequencyRange 5MHzto1002MHz
FrequencyResolution 50kHz
FrequencyTuning Frequencyorchannel
InputImpedance 75ΩFtypeconnector
SpectrumAnalyzerSpan 2.5,6.25,12.5,25,62.5,125,250,500MHzandFull
SpectrumAnalyzerScale 5and10dB/div
ReversePathIngressScanRange Selectable5to42MHz,5to68MHz,and5to85MHz
ReversePathIngressScanMode Peak,Average,Min,andRealtime
DIGITAL
Demodulation ITUTJ.83AnnexA/B/Cstandard
Support 16,32,64,128and256QAM,QPSK
SymbolRate 2to6.9MS/sec
DFEfilter On/Off
DynamicRange ‐30to+60dBmV
C/N upto45dB
MER upto40dB
Accuracy ±2dB
Resolution 0.1dB
PreBERandPostBER(AnnexB) 1.0E3to1.0E8
BER(AnnexA/C) 1.0E3to1.0E8
ConstellationDisplay 16,32,64,128and256QAM
ConstellationZoomCapability

ConstellationGraphicalRepresentation

ANALOG
DynamicRange ‐30to+60dBmV
V/A upto30dB
C/N upto45dB
Accuracy ±2dB
Resolution 0.1dB
CSO/CTB

ChannelPlans
FactoryChannelPlans StandardCATV,Return,HRC,IRC,Broadcast,CCIR
CustomChannelPlans(LearningPlan) upto16channelplans
SystemScanChannels upto100channels(analogand/ordigital)
SystemScanMeasurements LevelbarrepresentationandC/NBER/MERoftheselected
TiltChannels upto100channels(analogand/ordigital)
TiltSelectableMarkers

TiltFactoryProfiles Trunk,Tap,Endofline,GroundBlock,ModemSetup
TiltCustomProfiles upto10profiles
VoltmeterRange 9Vto150V
VoltmeterAccuracy ±1%
HumRange 2to5%
HumAccuracy ±1%
DigitalMeasurements
H30 Digital Processing
Handheld QAM Meter
Specifications Subject To Change Without Notice Rev 0-13 ©Toner Cable Equipment, Inc.
TECHNICAL SPECIFICATIONS