Problem: Burner will not light using igniter
Please review the Helpful Tips on page 15 for common fixes to this problem.
Possible Cause 1: Electrode and burners are wet.
-Wipe dry with cloth.
-Please contact Living source
Possible Cause 2: Igniter battery is dead or backwards.
-Check that the AAA battery is inserted correctly in the igniter (see page 10) or
replace the battery. Make sure the plastic wrap on the battery has been removed.
Possible Cause 3
: Igniter P i n cracked or broken - sparks a crack.
Possible Cause 4: Bad Igniter
-Please contact Living Source
Possible Cause 1: No Gas Flow
-Check if the LP gas tank is empty. If empty, replace and refill. If the propane
tank is not empty, refer to “Problem: Sudden drop in gas flow” on the
following page.
Possible Cause 2: Coupling nut and regulator not fully connected.
-Turn the coupling nut about one half to three fourths a turn, until you
feel a solid stop. Do not use tools, tighten by hand only.
Possible Cause 3: Obstruction of gas flow.
- Check for bent or kinked hose.
- Clean the venturi.
Possible Cause 4: Spider webs or insect nest in the venturi.
Possible Cause 5: Burner ports clogged or blocked.
-Reference “Problem: Irregular flame pattern” on the following page. Clean the
burner ports as described there.
Problem: Burner will not light with match
Problem: The fire table emits a lot of black smoke when in use
Possible Cause 1: Hose from gas fire table is pinched.
-Make sure the hose is not pinched between the
fire table and the source of the gas.
Possible Cause 2: Flame is being obstructed at burner ports.
Possible Cause 3: Mixing chamber of the burn tube is blocked or obstructed.
-Make sure that the gas ports on the burner are free
of any lava rocks/fire glass so that the flame can flow
naturally.
-Clear out the mixing chamber located before the Venturi.
Troubleshooting
Venturi
Coupling Nut