User manual

59
Indirect measurement with two reference points (ill. 2)
1. Turn on the device.
2. Push the button
(6) until the display shows the symbol . First
the hypotenuse, then the cathetus is measured.
3. When the hypotenuse of the symbol
ashes, push the button
to take a measurement. The measured value is moved to the upper
line. The next leg (cathetus) ashes.
4. Push the button
to turn the target laser back on and again to
take a measurement. The measured value is moved to the middle
line. When measuring the horizontal leg, hold the device as level
as possible.
5. The calculated height is shown in the lower line.
Delete the measurement by pushing the button .
Indirect measurement with three reference points (ill. 3)
1. Turn on the device.
2. Push the button
(6) until the display shows the symbol .
3. The rst leg to be measured ashes in the symbol (
). Push the
button to take a measurement. The measured value is moved
to the upper line.
4. Measure the next legs (heed the symbol). When measuring the
horizontal leg, hold the device as level as possible.
5. The calculated height is shown in the lower line.
Delete the measurement by pushing the button .