User manual

67
25. Tips and notes
Light refraction and sunlight can cause measuring errors during
outdoor use. Perform measurements under suitable light conditions.
When using the product outdoors, protect it from moisture and
humidity.
The following surfaces can affect the measurement due to their
physical characteristics:
- Transparent surfaces (e.g. glass, water)
- Reecting surfaces (e.g. glass, shiny metals)
- Porous surfaces (e.g. insulating materials)
- Structured surfaces (e.g. roughcast, natural stone)
Attach the hand strap to the eyelet (N).
If needed, mount the product to a suitable tripod with a socket
diameter of 6.35 mm (1/4”).
26. Troubleshooting
Code Cause Solution
Err01
Measurement range
exceeded
Observe the correct
measurement range.
Err02
Reected signal too
weak
Choose another measurement
surface.
Err03
Beyond display range
(max. value: 99999)
Measure in smaller increments.
Err04 Calculation error Repeat the process.
Err05 Batteries weak Replace the batteries.
Err06
Beyond/below
operating temperature
Observe the correct operating
temperature.