Instructions

61
14. Technical data
Display ..............................................................4000 Counts (digits)
Measurement interval .......................................approx. 2-3 measurements/second
AC measurement method .................................True RMS, AC-coupled
Test lead length ................................................approx. 90 cm
Measuring impedance ......................................≥10MΩ//10pF(Vrange)
Measuring terminal clearance ..........................19 mm (COM-V)
Low battery indicator ........................................Batteryvoltage≤6V
“Dangerous voltage” indicator ..........................≥30V/AC-DC
“Range exceeded” alarm ..................................≥600V/AC-DC,≥10A/AC-DC
“OL” (overload) alarm .......................................≥610V/AC-DC,≥10,10A/AC-DCormeasurement>4400counts
Automatic power-off .........................................after approx.15 minutes (can be manually disabled)
Current consumption (auto off) .........................<30 µA
Operating voltage .............................................9 V block battery
Operating conditions .........................................0 to +40 °C (<75 % RH)
Operating altitude .............................................max. 2000 m above sea level
Storage temperature .........................................-10 °C to +50 °C
Weight ..............................................................approx. 391 g
Dimensions (L x W x H) ....................................178 x 85 x 40 mm
Measuring category ..........................................CAT III 600 V
Pollution degree ................................................2
Safety regulations .............................................EN 61010-1
Measuring tolerances
Accuracy in ± (% of reading + display error in counts (= number of smallest points)). These accuracy readings are
valid for one year at a temperature of +23 °C (± 5 °C) and a relative humidity of less than 75 % (non-condensing). If
themultimeterisusedoutsideofthistemperaturerange,usethefollowingcoefcienttocalculatetheaccuracy.+0.1x
(speciedaccuracy)/1°C
The accuracy of measurements may be affected when the multimeter is used in a high-frequency electromagnetic
eld.