Operation Manual

32
c) Distance Measurement in Permanent Measuring Mode
The laser distance meter has a permanent measuring mode. Continuous distance measurement
are performed automatically here (max. 2 measurements per seconds, depending on the surface/
distance) and the value is displayed in the lower line (4).
To activate the permanent measuring mode, the laser distance meter must be activated (see
chapter 9. a).
Keep the measuring button (B) pushed for about 2 seconds until the measuring mode
switches from the individual measurement to the continuous measurement mode:
Individual measurement
Continuous measuring mode
The laser distance meter now performs continuous measurements and indicates the measured
value in the bottom line (4).
To stop the permanent measurement mode temporarily, briey push the power button “ (D).
The laser goes out. To continue, briey push the measuring button „ “ (B).
To terminate the permanent measuring mode, briey push the power button “ (D) so that
the measuring mode has stopped.
Then briey push the power button again (D). The laser distance meter then switches
back to the individual measurements.
If the measured value still displayed is to be deactivated, briey push the power button
“ (D).