c) Distance Measurement in Permanent Measuring Mode
The laser distance meter has a permanent measuring mode. Continuous distance measurement
are performed automatically here (max. 2 measurements per seconds, depending on the surface/
distance) and the value is displayed in the lower line (4).
• To activate the permanent measuring mode, the laser distance meter must be activated (see
chapter 9. a).
• Keep the measuring button „ “ (B) pushed for about 2 seconds until the measuring mode
switches from the individual measurement to the continuous measurement mode:
Individual measurement
Continuous measuring mode
• The laser distance meter now performs continuous measurements and indicates the measured
value in the bottom line (4).
• To stop the permanent measurement mode temporarily, briey push the power button „ “ (D).
The laser goes out. To continue, briey push the measuring button „ “ (B).
• To terminate the permanent measuring mode, briey push the power button „ “ (D) so that
the measuring mode has stopped.
Then briey push the power button „ “ again (D). The laser distance meter then switches
back to the individual measurements.
If the measured value still displayed is to be deactivated, briey push the power button
„ “ (D).