Instructions

25. Tips and useful information
Measuring errors may occur when operating the product
outdoors due to light refraction or sunlight. Perform
measurements in suitable light conditions.
Due to their physical properties, the following surfaces
may falsify the measurements:
- Transparent surfaces (e.g. glass, water)
- Reective surfaces (e.g. glass, shiny metal)
- Porous surfaces (e.g. insulating materials)
- Structured surfaces (e.g. roughcast, natural stone)
Use a tripod (not included) in order to achieve consistent
results.
26. Troubleshooting
Code Cause Solution
204 Calculation error Repeat the process.
208 Overcurrent Contact your retailer.
220
Weak batteries/
rechargeable
batteries
Replace or recharge
the batteries.
252
Temperature too
high
Observe the operat-
ing temperature
range.
253 Temperature too low
255
Reected signal
too weak or
measurement takes
too long.
Select a different
measurement
surface.
256
Reected signal too
strong
28