25. Tips and useful information
• Measuring errors may occur when operating the product
outdoors due to light refraction or sunlight. Perform
measurements in suitable light conditions.
• Due to their physical properties, the following surfaces
may falsify the measurements:
- Transparent surfaces (e.g. glass, water)
- Reective surfaces (e.g. glass, shiny metal)
- Porous surfaces (e.g. insulating materials)
- Structured surfaces (e.g. roughcast, natural stone)
• Use a tripod (not included) in order to achieve consistent
results.
26. Troubleshooting
Code Cause Solution
204 Calculation error Repeat the process.
208 Overcurrent Contact your retailer.
220
Weak batteries/
rechargeable
batteries
Replace or recharge
the batteries.
252
Temperature too
high
Observe the operat-
ing temperature
range.
253 Temperature too low
255
Reected signal
too weak or
measurement takes
too long.
Select a different
measurement
surface.
256
Reected signal too
strong
28