Serial port commands
Command Description
C?0 Help
C00 Restore factory settings
C10 Check the temperature of all channels
C11 Check the temperature of Channel 1
C12 Check the temperature of Channel 2
C13 Check the temperature of Channel 3
C20 Open all channels
C21 Open Channel 1
C22 Open Channel 2
C23 Open Channel 3
C24 Open desoldering pen
C30 Close all channels
C31 Close Channel 1
C32 Close Channel 2
C33 Close Channel 3
C34 Close desoldering pen
Indicatesthedatatobelledinbytheuser,_indicatesnoneedoflling
C41 Temperature unit selection °C 0; °F 1
C42 Tone switch On 0; Off
If the input value has less than 3 digits, use 0 to supplement;
C51 Temperature value setting of Channel 1 (150-500°C/302-932°F)
C52 Temperature value setting of Channel 2 (150-500°C/302-932°F)
C53 Temperature value setting of Channel 3 (150-500°C/302-932°F)
C54 Air ow value setting of Channel 3 (150-500°C/302-932°F)
C61 Temperature calibration value of Channel 1 (-50-50°C/-90-90°F)
C62 Temperature calibration value of Channel 2 (-50-50°C/-90-90°F)
C63 Temperature calibration value of Channel 3 (-50-50°C/-90-90°F)
C71
Sleep time setting of Channel 1 (0 - 120)
(default value at delivery is 0 minute, no sleep)
C72
Sleep time setting of Channel 2 (0 - 120)
(default value at delivery is 0 minute, no sleep)
C80 Parameter locking for all channels Unlock 0 Lock 1
C81 Parameter locking for channel 1 Unlock 0 Lock 1
C82 Parameter locking for channel 2 Unlock 0 Lock 1
C83 Parameter locking for channel 3 Unlock 0 Lock 1
Error codes
Code Possible reasons
E-1 : thermal
fuse fault
The heating unit (of the soldering iron, desoldering gun, soldering tweezers
or hot air nozzle) is faulty or there is a contact problem.
E-2: sensor
alarrn
The temperature sensor (of the soldering iron, desoldering gun, soldering
tweezers or hot air nozzle) is faulty or there is a contact problem.