Operation Manual

FT 92 English
www.toolland.eu 20
Pos. 3 (Minimum)
Open the valve on the gas cylinder.
Put the control knob in ‘Start position and
Maximum heating(Pos.1) and press
down.
After 10 seconds while holding the
control knob in pressed condition push
the piezoelectric ignition button fully
down. It could be necessary to push the
piezo button several times before the
pilot is lighted. Each time you push the
piezo button down you will hear a clicking
sound as well as see a spark on the pilot
burner. This spark will light the pilot.
Once the pilot is lit, continue on holding
the gas control knob in the pressed
position for further 20 seconds. The
heater will heat at Maximum (Pos.1)
Now you can put the control knob in the
desired heating position. Pos.2 =
Medium, Pos.3 = Minimum.
To turn off the device, completely close
the gas cylinder valve.
Do not move the heater when it is
operating.
6. MAINTENANCE
Always turn off the appliance before
cleaning it and wait till it is cooled
completely.
To clean the outside of the heater, use a
soft cloth soaked with water and a liquid
detergent. Do not use scouring pads or
abrasive products. Do not use water or
abrasive products.
Regularly inspect the atmosphere
analyzer and the aeration holes.
Regularly check the condition of the
connections. Check the condition of the
hose and the pressure regulator every
time the gas cylinder is changed.
Take care not to hit or damage the
surface of the burner, the fittings and gas
tubes, the tap and all the other
components of the gas circuit.
We recommend that you have the heater
inspected once a year by a qualified
professional.
If you decide not to use the heater for an
extended period, you must follow the
instructions bellow:
- Close the tap on the cylinder and
disconnect the pressure regulator
from the cylinder.
- Store the cylinder in a well-ventilated
room, far from inflammable or
explosive materials and preferably
outside your home. Never store the
cylinder in a basement or attic.
- The heater must be stored in a dry
place and protected from dust. It is
recommended to store the heater in
its original packaging.
7. ENVIRONMENT
Should your appliance need replacement
after extended use, do not put it in the
domestic waste but dispose of it in an
environmentally safe way.
8. WARRANTY
Refer to the enclosed warranty conditions for
the terms and conditions warranty.
9. TECHNICAL SPECIFICATIONS
Standen
3
Vermogen
3,2kW
Gas type
Propaan/Butaan
Gas Category
I3+
Mbar
28-30/37
Ignition
Piezo
Consumption
235g/u