User's Manual Part 1

Configuration
HiPer XT Operator’s Manual
2-24
Also, if Always is enabled, your receiver will automatically start
logging data (to a newly created or an existing file) in the
following three cases:
After turning on the receiver using the Power key.
After resetting the receiver (using PC-CDU or pressing the
Reset key).
After taking the receiver out of Sleep Mode.
Table 2-2. Data Recording Parameter Behavior
Before
Power
Failure
Enabled Radio Button Results
Off On Always
1
Receiver data
logged to file
specified.
Data logging will
not resume when
power is restored.
Receiver will
resume data
logging to the
same file when
power is restored.
Receiver will
resume data logging
to the same file
when power is
restored.
2
Receiver data
logged to
default file.
Data logging will
not resume when
power is restored.
A new log file will
open when power
is restored and
data will log to
this file.
A new log file will
open when power is
restored and data
will log to this file.
3
File specified;
receiver data
logging not
started.
No file will open
with this name.
Data logging will
not start when
power is restored.
No file will open
with this name.
Data logging will
not start when
power is restored.
A log file with this
name will open and
data logging will
start after power is
restored.
4
No file
specified;
receiver data
logging off.
Data logging will
not start when
power is restored.
Data logging will
not start when
power is restored.
A log file with a
default name will
open and data
logging will start
after power is
restored.