User's Manual Part 1

Configuration
HiPer XT Operator’s Manual
2-38
ensure reliable radio communication between the base
and rover receivers.
6. From the Protocol Mode control, select the appropriate link
protocol among the following available:
Transparent w/EOT Character
Transparent w/EOT Timeout
•Fast Async
Use the same protocol as at the base station.
7. If you select Transparent w/EOT Character, the EOT
Character (Dec) field will be displayed. In this field enter a
decimal value (usually a control character). Once the specified
character is found in the incoming data stream, the modem begins
data transmission.
8. If you select Transparent w/EOT Timeout, the TX ACK
Timeout (in x10 ms) field will be displayed. In this field enter an
integer value between 1 (10 ms) and 50 (500 ms). Once the
timeout between incoming data exceeds the specified value, the
modem begins data transmission.
9. From the Output Power control, set the level of RF transmit
power to 10 mW.
10. Click on the FCS tab.
11. From the Mode control, select Slave.
12. In the Free Scan Frequency List control, you will see the
frequencies that are used in the scan process. Double-click a
frequeny in the list to exclude/include this frequency from/to the
scan process. You may also select/deselect all frequencies at one
time with the Select all and Deselect all controls.
NOTICE
NOTICE
For FCS to operate properly, you must select at least two
frequencies. Also the selected frequencies must be the
same as at the base radio-modem.