User's Manual Part 1

Setup and Survey
HiPer XT Operator’s Manual
3-6
greater accuracy than single-frequency receivers over long baselines
or during ionospheric storms. Secondly, dual-frequency receivers
need far less observation time to reach the desired accuracy
requirement.
After the survey completes, data the receivers collect can be
downloaded onto a computer and processed using post-processing
software (for example, Topcon Tools).
The procedure that follows describes the steps the operator should
take to perform a Static Survey using MINTER.
1. Connect your receiver and computer. See “Connecting the
Receiver and a Computer” on page 2-10 for this procedure.
2. Open PC-CDU, click ConfigurationReceiverMINTER
and specify the following parameters, then click Apply
(Figure 3-2):
Recording interval – 15 seconds
Elevation mask angle – 15 degrees
File name prefixlast 3 digits of receiver serial number
LED blink mode switch – enable to start and stop static data
recording using the FN key
Figure 3-2. Configure MINTER