User's Manual

Troubleshooting
HiPer Ga/Gb Operator’s Manual
6-12
The Bluetooth module’s processor is overloaded.
1. Put your receiver in Zero Power Mode. See “Entering
Zero Power Mode,” on page 5-16 for details.
2. Press the Reset key for about one second to return the
receiver to normal mode.
3. Reconnect to the Bluetooth module.
BTCONF error message: Open COM# port failed: Access is
denied
Another application uses the computer port dedicated for
connection.
Close the application, then reconnect.
Connect the receiver via another unused computer port.
After searching for available devices, none are discovered
The receiver is not receiving power.
Check that the receiver is getting power and is turned on.
Check that the power cable is attached to the port marked
“PWR.
Unplug the cable, then securely and properly reconnect it to
the receiver.
If the power cable is damaged, contact your Dealer to
purchase a new cable.
The receiver’s Slot 3 is turned off.
1. Connect your receiver and a computer using an RS232
cable (see “Establishing an RS232 Cable Connection,” on
page 2-16).
2. Click ConfigurationReceiverGeneral.
3. In the Turn on/off Slots area, enable the Slot 3 (B) check
box.
Can see the icon for the receiver’s Bluetooth module on the
computer screen, but cannot connect to it
Device security settings probably differ.