5. Select ConfigurationReceiver.
6. Click Set all parameters to defaults (Figure 3-7).
Figure 3-7. Set All Parameters to Defaults
7. Click the MINTER tab, enter the following settings
(Table 3-4), and then click Apply (Figure 3-8).
NOTICE
Click Apply after making any configuration
change; otherwise, the receiver will not register the
change.
Table 3-4. Receiver Parameters for the MINTER Tab
Parameter Base Receiver Rover Receiver
Recording
interval
Enter 15 seconds.
Elevation
mask angle
Enter 15 degrees.
File name
prefix
Enter a unique ID, such as the last 3 digits of receiver’s serial
number.
FN key mode (starts/stops data recording using the FN key)
For Static data recording,
select LED blink mode switch.
For RTK data recording,
select Occupation mode
switch.