User's Manual

HiPer Ga/Gb Configuration
HiPer Ga/Gb Operator’s Manual
3-22
Values are 0 to [2
31
-1]; default value is 0 (zero). Zero means that
an unlimited number of log files are created.
Files (remain) – specifies the number of files left for the receiver
to create in AFRM. Values are 0 to [2
31
-1]; default value is zero.
Automatically remove old files – when no free memory is
available to log data, automatically removes the earliest log file. If
this parameter is enabled, then the receiver erases the file with the
earliest file creation time/date. AFRM must be enabled to use this
FIFO (First-In, First-Out) feature. The default value is off
(disabled).
FN Key Mode parameter Use these two radio buttons to program
how the receiver reacts when pressing the FN key.
LED blink mode switch – pressing the FN key toggles between
the MINTER’s normal/extended information modes and start/
stop data recording of Static survey.
– Pressing the FN key for less than 1 second changes the
information mode (Normal or Extended Information Modes).
– Pressing the FN key for 1 to 5 seconds starts or stops data
recording (Static post-processing mode).
Occupation mode switch – pressing the FN key (less than one
second) will insert a message into the corresponding log file,
indicating that the survey type changed from static to kinematic,
or vice versa. If the REC LED blinks green, the current mode is
dynamic, if it blinks orange, the current mode is static. For more
details, see Table 1-2 on page 1-12 and refer to the PC-CDU
Reference Manual.
Initial Data Collection Dynamic Mode parameter These radio
buttons specify the starting occupation type descriptor inserted at the
beginning of receiver files logged. Select Static or Kinematic to
specify that the corresponding log file starts with a static (STOP) or
kinematic (GO, Trajectory) occupation, respectively.
NOTICE
The receiver’s memory holds up to 512 files.