User's Manual

Static Surveying for Base Stations
P/N 7010-0816
4-9
parameter” on page 3-21 for information on setting these
functions.
Figure 4-6. FUNCTION Button Functions
To toggle between post-processing modes, press the FN key for
less than 1 second when “Occupation mode switch” has been enabled
using PC-CDU.
To change the information mode of the receiver, press the FN key
for less than 1 second when “LED blink mode switch” has been
enabled using PC-CDU.
To change the baud rate of the receiver’s serial port, press the
FN key for 5–8 seconds. This is useful if the data collector does not
support the rate that the receiver port is set to.
After about five seconds, the REC LED becomes red. Release the FN
key during the next three seconds.
Static Surveying for Base
Stations
Static surveying is the classic survey method, well suited for all kinds
of baselines (short, medium, long). At least two receiver antennas,
plumbed over survey marks, simultaneously collect raw data at each
end of a baseline during a certain period of time. These two receivers
track four or more common satellites, have a common data logging
rate (5–30 seconds), and the same elevation mask angles. The length
of the observation sessions can vary from a few minutes to several
Press the FN button for 1–5
seconds to start/stop data logging.