User's Manual

Indicator
Rotating laser battery warning display
A flash shows that the rotating laser power is low.
(This function is not usable to the rotating laser which does
not have the function to output alarm signal.)
Goes out:
Battery is sufficient. (When Mode 1 is selected, the lamp will
light up.)
Flashes slowly:
The power is low, but sensor is still usable.
Flashes quickly:
Dead battery. Replace the dry battery with new one.
Mode1
Mode2
Mode3
Mode4
Precision mode
LS-B110/LS-B110W Battery remaining display
Battery remaining display LED
Rotating laser battery
remaining warning LED
It is possible to change the detective precision of the
instrument.
Please select Mode 1 to 4 according to the objective of the
operation.
Pressing the detective precision (Mode) switch will change
the mode and the corresponding LED lamp will light up.
(During battery remaining display shown below, the lamp
will flash.)
Battery remaining for the LS-B110/LS-B110W will be displayed
at 3 levels.
Indicator (LED)
Detective precision
Mode1: ±3mm
(0.009ft)
Mode2: ±6mm (0.019ft)
Mode3: ±15mm (0.049ft)
Mode4: ±30mm (0.098ft)
±15mm/±0.05ft
(30mm/0.1ft width)
±30mm/±0.1ft
(60mm/0.2ft width)
When the laser
beam is off to the top
or to the bottom
Flashes slowly
Flashes quickly
±50mm/±0.16ft
(100mm/0.33ft width)
±70mm/±0.23ft
(140mm/0.46ft width)
±125mm/±0.41ft
(250mm/0.82ft width)
Flashes quickly
Flashes slowly
Flashes more slowly
Laser beam positions and display patterns
Height alert warning of rotating laser
A flash signifies that the height alert function of rotating
laser is operating.
(This function is not usable to the rotating laser which does
not have the height alert and the function to output alarm
signal.)
Flashes
Power-save function
Flashes
The instrument turns the power-save mode after detecting
no laser beam for more than approx. five minutes.
During the power-save mode, LED (1 yellow, 1 red) will
flash.
(The mode is canceled automatically when the instrument
detects a laser beam again. The mode can also be can-
celed by pressing the power switch again.)
Auto-cut off function
The power will be turned off automatically after detecting no laser beam for
more than approx. 60 minutes.
(To turn on the laser sensor, press the power switch again.)
* When turning the power on by pressing the power switch for more than
5 seconds, the power-save and the auto-cut off functions may be inval-
idated.
Connector for external communication
The LS-B110/LS-B110W can be used as the laser detecting sensor for any TOP-
CON machine control system by connecting the communication cable to the con-
nector for external communication. (Please contact your sales agent for details.)
Connecting the connector cable PC-18 (sold separately) to the connector for
external communication will enable the use of the LS-B110/LS-B110W from an
external power supply. When the instrument is operated with the external power
supply, the power-save and the auto-cut off functions will be invalidated. The LS-
B110/LS-B110W will turn on when connection is made to external power supply.
The power switch of the instrument will not function when an external power sup-
ply is used. Wireless communication will not function when using external com-
munication or an external power supply.