Installation Guide
Model: TDHOS5
Dual Technology
Humidity/PIR Motion Sensor
with Interchangeable Face Cover
Power.............................................................................................120VAC, 60Hz
Resistive................................................................................................360 Watts
Tungsten................................................................................................500 Watts
Electronic Ballast/ LED ............................................................400VA/ 400 Watts
Light and Fan Time Delay....................................15s, 10 mins, 20 mins, 30 mins
Motor...........................................................................................................1/4 HP
Humidity range.................................................................................45%-80% RH
PIR coverage............................................................................................600sq.ft
INSTALLATION INSTRUCTIONS
WARNING
Read and understand these instructions before installing. This device is intended for
installation in accordance with the National Electric Code and local regulations. It is
recommended that a qualified electrician performs this installation. Make sure to turn
off the circuit breaker or fuse(s) and make sure power is off before wiring the device.
Use copper wire only.
Turn the power off at the circuit breaker before installing the Sensor.
COVERAGE
As illustrated in the figure below, the TDHOS5 has a 180° detection range with
a maximum distance of 24’ detection in front of the sensor and 12' on the sides.
For maximum results, the sensor must be properly installed between the height
of 4’ to 5’ and away from obstructions such as walls, furniture and transparent
barriers like Low-E glass.
Max. 12’
on the sides
Max. 24’
in the front
SPECIFICATIONS
WIRING DIRECTIONS:
1. Remove the wall plate.
2. Remove existing switch from wall box and prior to disconnecting wires,
identify the wires and label as needed.
3. Remove wires from existing switch.
4. Follow the diagram below to reconnect the TDHOS5 humidity sensor.
WARNING: The white wire you see in the wall box is not always the
neutral wire. Verify whether the power enters the wall or
ceiling box first.
Function 1: Time Delay for the light and fan
Press and hold the light button for eight seconds until the solid green
LED lights up (the LED will stay on).
PROGRAMMING
• During programming, ONLY the Light Button will be used
• Pay close attention to the Green LED lights as it will flash to indicate successful
programming steps and each time the button is pressed while making selections.
• Once the program is saved, the load (lights on your ceiling/ wall) will turn OFF.
• After each step, there are only 20 seconds to make the next programming
selection. If a selection has not been made, time will expire and the LED light will
flash 3 times and exit programming mode.
There are 2 Programmable Functions
• Setting 1 (Default): 15 seconds/ 10 minutes. When selected, the time delay
will be 15 secs. After 5 minutes, the time delay defaults to 10 minutes
• Setting 2: 20 minutes
• Setting 3: 30 minutes
• Setting 1: Low humidity sensitivity 45% (requires little
humidity to trigger)
• Setting 2 (Default): Medium humidity sensitivity 65%
• Setting 3: High humidity sensitivity 80% (requires high
humidity to trigger)
Function 2: Humidity level (Humidity Range 45% - 80%)
STEP 1: Enter Programming Mode
How to change the color cover/ push button.
Start by removing the wallplate if attached.
REMOVAL
Push down on the cover/ push button
to release, then pull away from main body.
REATTACH
Align the latch pins to the unit, push the cover/
button against the main body, then slide up until
its locked into place
• Press the light button the same number of times as the Function Number you would
like to program (1x for Function 1 and 2x for Function 2)
STEP 2: Choose the Function
• Press the light button the same number of times as the Setting
Number for that function (For example in Function 1: Press the button
2 times to select 20 minutes).
After the last button is pressed the sensor will flash back the
current setting for that function 10 times at two-second
intervals. If no selection has been made, the device will exit
programming mode.
STEP 3: Choose the Setting
• Press and Hold the light button for eight seconds. The LED light will
flash 3 times indicating that the settings are saved then the load will
turn OFF.
STEP 4: Save the Settings
To progam the humidity sensor, you must first enter programming mode, then choose
function 1 or function 2, then select 1 of 3 settings within each function
After you select the function, the LED indicator will indicate the current
setting by blinking 1x for Setting 1, 2x for Setting 2, and 3x for Setting 3
If no selection has been made, the device will exit programming mode.
Neutral
Light
Ground
Hot
Fan
Power