User Manual

SAFETY RELATED SYMBOLS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The symbol is used to indicate that
some hazardous live terminals are
involved within this apparatus, even
under the normal operating conditions.
The symbol is used in the service
documentation to indicate that specific
component shall be only replaced by
the component specified in that
Documentation for safety reasons.
Protective grounding terminal.
Alternating current /voltage.
ON: Denotes the apparatus turns on.
OFF: Denotes the apparatus turns off, bec-
ause of using the single pole switch, be sure
to unplug the AC power to prevent any
electric shock before you proceed your
service.
WARNING: Describes precautions that
should be observed to prevent the danger
of injury or death to the user.
CAUTION: Describes precautions that
should be observed to prevent danger of the
apparatus.
WARNING
Power Supply
Ensure the source voltage matches the
voltage of the power supply before turning
ON the apparatus.
Unplug this apparatus during lightning
storms or when unused for long periods
of time.
External Connection
The external wiring connected to the output
hazardous live terminals requires installation
by an instructed person, or the use of ready-
made leads or cords.
Do not Remove any Cover
There are maybe some areas with high
voltages inside, to reduce the risk of electric
shock, do not remove any cover if the power
supply is connected.
The cover should be removed by the qualified
personnel only.
No user serviceable parts inside.
Fuse
To prevent a fire, make sure to use fuses
with specified standard (current, voltage,
type). Do not use a different fuse or short
circuit the fuse holder.
Before replacing the fuse, turn OFF the
apparatus and disconnected the power
source.
Protective Grounding
Make sure to connect the protective
grounding to prevent any electric shock
before turning ON the apparatus.
Never cut off the internal or external pro-
tective grounding wire or disconnect the
wiring of protective grounding terminal.
Operating Conditions
Hazardous live terminal .
Disposing of this product should
not be placed in municipal waste
and should be separate collection.
This apparatus shall not be exposed to
dripping or splashing and that no objects
filled with liquids, such as vases, shall be
placed on this apparatus.
1
16
Impedance
Equalizer
Crosstalk
Main Mix Section
Dielectric Strength
Insulation Resistance
Power supply
Physical
Microphone Input
All Other Input
All Other Outputs
High
Mid
Low
Adjacent Input
Input to Output
Line output
MIC output,MONO output
Max output
Noise (Bus noise)
Between Live+Negative Earth
Between Live+Negative IN/OUT
Terminal(Positive+Negative)
Between Live+Negative Earth
(A Voltage of 500VDC)
Between Live+Negative IN/OUT
Terminal(Positive+Negative)
(A Voltage of 500VDC)
Main voltage
Dimension (WxDxH)
Weight
1.4k Ohms
10k Ohms or Greater
120 Ohms
15 dB @12 kHz
12 dB @2.5 kHz
15 dB @80 Hz
-82 dB @ 1KHz (CH level at max, EQ at MID, MAIN
level and other at min, SW at line)
-70dB@1kHz(Ch1-6); -68 dB @ 1KHz (CH7-12)
0 dBu( 2dBu) Balanced(CH level
&MAIN & EQ at MID, other at min, sw at line)
0 dBu( 2dBu) Unbalanced, 1/4" Jacks(CH level
&MAIN & EQ at MID, other at min, sw at line)
+21 dBu Blanced/Unbalanced, 1/4" Jacks
-83dB @ 20Hz~22KHz (channel & MAIN level & EQ
at MID, other at min, sw at line)
1500VAC at Test,Frequency 50/60Hz,Leakage Current:
5mA for 1minute
3000VAC at Test,Frequency 50/60Hz,Leakage Current:
5mA for 1minute
2M
4M
220~240VAC/110~120VAC ~ 50/60Hz or 24VDC
483*195*44mm
Net :2.9kg
PROFESSIONAL MIXER PREAMPLIFIER