User Manual
POWER CONSUMPTION: 600W
AUX
PRE OUT
AMP IN
LEVELLEVEL
Line MicLine Mic
INPUT 2
MUTE
SEN.
INPUT 1
Phantom
24V
Phantom
24V
TEL.
TEL. INPUT
1W
8
600
HOTCOMGND
++
--
110-120V~ 220-240V~
DC
a24V 20A
25V
COM
100V70V
4
+
-
COMCOMCOM Z1 Z2 Z3 Z4
SINGLE ZONE: 120W(MAX)
TOTAL ZONE: 240W(MAX)
SINGLE ZONE: 120W(MAX)
TOTAL ZONE:
240W(MAX)
LINE OUT
GND
110-120V~50/60Hz FUSE:T12AL 250V
220-240V~50/60Hz FUSE:T6.3AL 250V
CLASS 2 WIRING
CLASS 2 WIRING
Line Mic
INPUT 3
Phantom
24V
Line Mic
INPUT 4
Phantom
24V
PUBLIC ADDRESS AMPLIFIER
10
CONNECTION DESCRIPTION
Horn speaker
Sound column
Speaker
Microphone
Microphone stand
Speaker Tel.signal
24V
Battery
CD player
AM/FM tuner
Cassette recorder
Power amplifier
Equalizer
Mains
SAFETY RELATED SYMBOLS
The symbol is used to indicate that
some hazardous live terminals are
involved within this apparatus, even
under the normal operating conditions.
The symbol is used in the service
documentation to indicate that specific
component shall be only replaced by
the component specified in that
Documentation for safety reasons.
Protective grounding terminal.
Alternating current /voltage.
ON: Denotes the apparatus turns on.
OFF: Denotes the apparatus turns off, bec-
ause of using the single pole switch, be sure
to unplug the AC power to prevent any
electric shock before you proceed your
service.
WARNING: Describes precautions that
should be observed to prevent the danger
of injury or death to the user.
CAUTION: Describes precautions that
should be observed to prevent danger of the
apparatus.
WARNING
Power Supply
Ensure the source voltage matches the
voltage of the power supply before turning
ON the apparatus.
Unplug this apparatus during lightning
storms or when unused for long periods
of time.
External Connection
The external wiring connected to the output
hazardous live terminals requires installation
by an instructed person, or the use of ready-
made leads or cords.
Do not Remove any Cover
There are maybe some areas with high
voltages inside, to reduce the risk of electric
shock, do not remove any cover if the power
supply is connected.
The cover should be removed by the qualified
personnel only.
No user serviceable parts inside.
Fuse
To prevent a fire, make sure to use fuses
with specified standard (current, voltage,
type). Do not use a different fuse or short
circuit the fuse holder.
Before replacing the fuse, turn OFF the
apparatus and disconnected the power
source.
Protective Grounding
Never cut off the internal or external pro-
tective grounding wire or disconnect the
wiring of protective grounding terminal.
Hazardous live terminal .
Disposing of this product should
not be placed in municipal waste
and should be separate collection.
Before turning the product ON, make sure that
it is connected to Ground. This is to prevent the
risk of electric shock. Never cut internal or
external Ground wires. Likewise, never remove
Ground wiring from the Protective Ground
The apparatus shall be connected to a mains
socket outlet with a protective earthing
connection.
Terminal.