User Manual
11. RC-NET Input/Output Port
Control signal can transmit through this network port.
RC-Net is based on RS-485 transport protocol, which owns function of RS485 data exchange, to
realize large-scale real data transmit.
12. LAN& RC-NET Switch
Use this switch to choice Network control way, you can determine to control it by Ethernet or
RC-NET.
13. LAN Network Control Port
DLM808 can connect with Ethernet switch via this port. On LAN network control port, you can
see two LEDs, they are connection status indicator (green) and signal transmit indicator(yellow).
-- If the yellow LED goes out, means no signal transmits; while if yellow LED is on, but green one
goes out, means the device detects network, but no connection.
-- If green LED is on ,means network connects well.
14. Optional Module
Usually it is prepared for DANTE module to insert in, which can be used for audio input/output
expansion.
15. Power Inlet
Connect AC voltage,100-240VAC,50-60Hz.
16. Power Switch
Press it to turn on/off the device.
13 0x01 0x20 0x03 24 0x0A (1…8)
Byte 0:Mixer Input channel 1
Byte 1:Mixer Input channel 2
Byte 2:Mixer Input channel 3
…
Byte 8:Mixer Input channel 8
Byte 9:Mixer Digital Input 1
Byte 10:Mixer Digital Input 2
…
Byte 15:Mixer Digital Input 8
0x40
Device output the Output
Mixer status
14 0x01 0x20 0x03 24 0x0D 16Bytes ASCILL code 0x40 Set device name
15 0x01 0x20 0x03 8 0x0E 0x00 0x40 Get Device information
16 0x01 0x20 0x03 29
0x0E
Byte 0-15 : Device name ,ASCILL
Byte 16: Firmware Version
Byte 17-21: Device Serial Number
0x40
Device output Device
information
17 0x01 0x20 0x03 8 0x0F Preset Number 0-32 0x40 Recall Preset
8