PROGRAMMING INSTRUCTIONS
457Z
A DIVISION OF NSi INDUSTRIES, LLC
PLEASE READ ALL INSTRUCTIONS FIRST
ONE YEAR LIMITED WARRANTY: If this product
fails because of a manufacturing defect within
one year after purchase, we will, at our option,
either repair or replace it at no charge. Our
warranty does not cover damage caused by
accident, abuse or misuse. We assume no
further liability with respect to the sale or use
of this product. THIS WARRANTY IS IN LIEU
OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING THE WARRANTY OF
MERCHANTABILITY. We make no warranty with
respect to the fitness of any goods for the users
particular application. This warranty gives you
specific legal rights, and you also may have other
rights which vary from state to state.
It is our intent to provide accurate and current
specification information. However, in the interest
of product improvement, TORK may alter the
specifications or constructional details without
prior notice.
SET
MODE
ENTER
R
1.0 INSTALLATION INSTRUCTION
• Plug the timer into a 120VAC receptacle. If you charge battery
overnight, the unit can be removed and programmed without
AC power.
• Press the R (RESET) button by using an insulated tool.
• Press the ENTER to start the timer.
2.0 SET TIME AND DATE (CALD)
• Press the MODE button two times to display “CALD” flashing.
• Press the ENTER button to start current time setting mode.
• Using buttons change year, then press SET button.
• Continue to using and SET button to enter current month,
date, hour, minutes, and seconds.
• Press the ENTER button to save the current time setting and return
to clock mode.
3.0 SET SCHEDULE
• Press the MODE button to display “PROG” flashing.
• Press the ENTER button to display “PROG 1 ON”. This is the first
of 20 ON/OFF pairs. For first ON program, press SET. To go to other
programs, press .
3.1 SELECT DAYS
• All days are flashing. Use to choose a different set of days,
then press SET.
3.2 SET ON
• Use to choose:
a) “TIME” for a program with user set times
b) “SNUP” for a timer calculated sunrise time that will change daily
throughout the year.
c) “SNST” for a timer calculated sunset time that will change daily
throughout the year.
• Then press SET. If “TIME” selected: Use buttons to change
hour, then press SET button. Repeat for minutes.
3.3 SET OFF
• “PROG 1 OFF” is flashing on display. Press SET.
• All days are flashing. Use to choose a different set of
days, then press SET.
• Use to choose:
a) “TIME” for a program with user set times,
b) “SNUP” for a timer calculated sunrise time that will change daily
throughout the year.
c) “SNST” for a timer calculated sunset time that will change daily
throughout the year.
• Then press SET. If “TIME” selected: Use buttons to change
hour, then press SET button. Repeat for minutes. Press SET.
• Repeat steps for a total 20 ON and 20 OFF time settings.
• Press the ENTER button to finish programming set and return to
clock mode.
4.0 OPTIONAL SUNSET/SUNRISE TIME ZONES
• Press the MODE button three times to display “ZONE” flashing.
• Press the ENTER button to start Zone setting mode.
• Use the keys to display the correct zone.
---
NOTE: NUSA (Default) = North USA, CUSA = Center USA, SUSA = South
USA, ALAS = Alaska&Northern Canada, HAWI = Hawaii&Puerto Rico.
----
• Press the ENTER button to save the setting and return to clock
mode.
5.0 OPTIONAL SUNSET/SUNRISE OFFSET
---
NOTE: This mode displays calculated sunset/sunrise. You can change to
turn ON/OFF earlier or later with this mode.
---
• Press the MODE button four times to display “SUN± ” flashing.
• Press the ENTER button to start offset mode .
• Screen displays today’s SNUP (sun up) time flashing. Use or
to change default time.
• Press SET and screen displays today’s SNST (sunset) time flashing.
Use to change default time.
• Press ENTER to complete the setting and back to normal clock
mode.
6.0 OPTIONAL CHANGE DAYLIGHT SAVINGS TIME (DST)
---
NOTE: Skip this step for default daylight savings dates. Follow instructions
below only if you need to remove or change. MANU (Manual Mode) – no
DST change by timer. NEW mode - change dates to something other than
default dates.
----
• Press the MODE button five times to display “DST” flashing.
• Press the ENTER button to choose daylight savings times.
• Use the to choose daylight savings options.
a) The display shows “INIT”. For timer to follow current U.S. DST
dates, press ENTER.
b) The display shows “MANU”. For no DST adjustment, press ENTER.
c) The display shows “NEW”. For modified DST dates, consult
technical support phone line.
7.0 COUNTDOWN TIME SETTING
---
NOTE: Countdown mode will postpone the manual off for a preset period.
As an example, press button to turn off lights and timer will wait five
minutes before load is shut down. This will give you time to exit the room.
---
• Press the MODE button to display “PROG” flashing.
• Press the ENTER button to display “PROG 1 ON”.
• Press the once to bring the Countdown time setting.
• Press SET for the Countdown (dL) screen.
• Press to choose length of time.
• Press ENTER to complete the setting and back to normal clock
mode.
8.0 RANDOM ON/OFF TIME
• Pressed key SET & simultaneously to set the Random function.
Display shows “RND”.
• To Cancel Random function simply repeat above procedure. The
“RND” sign will disappear from display.
9.0 OVERRIDE BUTTON FUNCTIONS ( )
• Press one time to turn timer ON or OFF.
10.0 ACTIVATE COUNTDOWN
---
NOTE: To activate Countdown step 7 must be completed and the timer in
the ON position.
---
• Press
RATINGS
• 120V 15A, 1800W General Purpose
• 120V 15A, 1800W Resistive
• 120V, 960W Tungsten
• 120V 1/3 HP, TV-5
LI-846
FOR TECHNICAL SUPPORT: SOUTIEN TECHNIQUE : PARA COMUNICARSE CON EL SERVICIO TÉCNICO: techsupport@nsiindustries.com 877.230.7874
http://waterheatertimer.org/Tork-consumer-timers-and-manuals.html
__________________________________________________________________________

Summary of content (2 pages)