Operator's Manual

18
SET-UP INSTRUCTIONS
4. To tension rear counterbalance spring, rotate
counterbalance knob (Fig. 35) until distance between
center of anchor bolt opening and inside of frame X" is
as follows:
A. Distance X" is 50mm when equipped with 5 or
8 blade reels without baskets.
B. Distance X" is 15mm when equipped with 5 or
8 blade reels with baskets.
Figure 35
X"
5
4
3
1
2
1. Rear counterbalance knob
2. Anchor bolt
3. Spacer
4. Frame bracket
5. Counterbalance spring
IMPORTANT: These are recommended settings.
Readjust spring positions to attain optimum
performance and counterbalance. By raising
spring locations, cutting unit weight on ground is
reduced and traction is increased.
ADD REAR BALLAST
This unit complies with ANSl B 71.4-1984 Standard
and CE when equipped with rear ballast. Use the
following chart to determine weight or combinations of
weights needed.
Traction UnitWeight Required
Configuration
3 Wheel Axle
and equipped
with Baskets
Calcium Chloride in rear tire
and rear weights, Part No.
24-5790 and 24-5780.
4 Wheel Axle
and equipped
with Baskets
Calcium Chloride in rear tire
and rear weights,
Part No. 24-5780.
IMPORTANT: If a puncture occurs in a tire with
calcium chloride, remove unit from turf area as
quickly as possible. To prevent possible damage to
turf, immediately soak affected area with water.
Either Type 1 (77%) or Type 2 (94%) commercial
calcium chloride flake may be used.
Plain water freezes solid at 32_F(0_C). The 3-1/2
pound (1 .6 kg) calcium chloride to one gallon (3.8 L) of
water solution is slush free to -12_F (-24_C), and will
freeze solid at -52_ F (-46_C). The 5 pound (2.3 kg)
per gallon (liter) solution is slush free to -50_F
(-45_C) and will freeze solid at -62_F (-52_C).
Tires should be filled to approximately 75% capacity
(valve level with valve at the top).
ACTIVATE AND CHARGE BATTERY
(Fig. 36-37)
1. If Battery is not filled with electrolyte or activated,
bulk electrolyte with 1.260 specific gravity must be
purchased from a local battery supply outlet and
added to battery.
2. Remove access panel from rear of tower (Fig. 36).
1. Access panel
Figure 36
1
Wear safety goggles and rubber gloves
when working with electrolyte. Charge the
battery in a well ventilated place so gasses
produced while charging can dissipate.
Since the gases are explosive, keep open
flames and electrical spark away from the
battery; do not smoke. Nausea may result
if the gases are inhaled. Unplug charger
from electrical outlet before connecting to
or disconnecting charger leads from batĆ
tery posts.
CAUTION
3. Remove filler cap from battery and slowly fill each
cell until electrolyte is just above the plates.
4. Replace filler cap and connect a 3 to 4 amp battery
charger to the battery posts. Charge the battery at a
rate of 3 to 4 amperes for 4 to 8 hours.
5. When battery is charged, disconnect charger from
electrical outlet and battery posts.
6. Remove filler cap. Slowly add electrolyte to each
cell until level is up to fill ring. Install filler cap.