Form No. 3390-782 Rev A Road Lights with Brake Lights Kit Groundsmaster® 3400 Traction Unit Model No. 02917—Serial No. 315000001 and Up Installation Instructions Installation Loose Parts Use the chart below to verify that all parts have been shipped. Procedure 1 2 3 4 5 6 7 8 © 2014—The Toro® Company 8111 Lyndale Avenue South Bloomington, MN 55420 Description Use Qty.
Media and Additional Parts Description Use Qty. Installation Instructions 1 Read before installing and operating kit Parts Catalog 1 Use to reference part numbers 1 Preparing the Machine No Parts Required 1 Procedure 1. Park the machine on a level surface, lower the cutting unit, stop the engine, engage the parking brake and remove the key from the ignition switch. 2 2. Disconnect the negative (–) battery cable from the battery.
1 2 3 Note: Do not overtighten it as this will make the ROPS difficult to fold. 4 Note: If there is already a beacon kit fitted to the right side or a waste bin kit fitted to left side, use the existing bolt and the new M16 nyloc nuts provided with this kit. 25 11. Feed all electrical cables down the front of the ROPS frame and onto the electrical mount panel. 12. Connect the cables to the main wiring harness of the machine which is located on the electrical bulkhead (Figure 4), as follows: A.
1 2 3 g018247 Figure 6 1. Dowty seal, 1/4 inch 3. Pressure switch 2. Pressure switch adapter 1 4. Screw the pressure switch into this adapter (Figure 6). Torque the switch to 34 N-m (25 ft-lbs). 5. Working on the electrical bulkhead, plug the 3-pin connector of the electrical pressure switch cable to the corresponding connector located on the main wiring harness of the machine (Figure 4 and Figure 7). g018244 Figure 5 1.
4 Installing the Number Plate Bracket Figure 9 1. Red wire Parts needed for this procedure: 1 Number plate bracket 1 2-way tab housing connector 1 Flasher relay 1 Standard shorter relay 3. 2-way tab housing connector 2. Black wire 4. Connect the number plate light wiring to either the left or right, rear-light-assembly-wiring, 2-Pin electrical connector. 5. Plug the flasher relay into the left vacant relay socket and the standard shorter relay into the right vacant relay socket (Figure 10).
5 4 3 Installing the Front Lights 10 4 Parts needed for this procedure: 1 Center headlight mount 1 Right headlight mount 1 Left headlight mount 8 Bolt (M6 x 20mm) 8 Locknut (M6) 4 Bolt (M10 x 25mm) 4 Locknut (M10) 8 Washer (3/8 inch) 2 Mounting bracket 2 4-way tab housing connector 6 8 5 1 10 5 9 8 7 11 6 8 2 8 7 g018249 Figure 11 1.
9. Locate the two 4-pin connectors on the main wiring harness located near to the cutter manifold. 6 10. Connect the connector on the machine wiring harness with the Green/White wire to the identified left light assembly connector. (Figure 13). Installing the Control Panel Switches Parts needed for this procedure: Figure 13 1. Blue 2. Green/White 3. Red/White 4. Black 5. Green 6. 4-way tab housing connector 11.
1 2 G018336 1 2 Figure 17 1. Round plug—horn button 2. Rectangular plug—indicator switch g018292 Figure 15 1. Switch blank–light switch 9. Install the horn decal lining up the edges of the round and rectangular holes (Figure 18). 2. Switch blank–hazard switch 3 6. Pass the connectors and wires for the hazard and light switch though the switch hole . The hazard and hights connectors are on the shorter leads, the hazard connector is red and the light connector is black.
inches) from each edge of the engine cover (Figure 20). Make sure the surface is clean before mounting the reflectors. 1 2 G018338 1 Figure 19 1. Green/Red 2. Green/White 2 g018255 11. Connect the direction indicator switch to the connector lead instrument panel. The indicator connector is black and on the longer lead. Figure 20 1. 100 mm (4 inches) 12. In the control panel, there will be a pink and black/purple wire for the Horn button,. connect them to the horn button. 2. Reflector 8 13.
Operation Hazard Lights Specifications Depress the top of the hazard light switch, all 4 indicator lamps will flash. The ignition switch does not need to be on for these to operate. Voltage: 12 V Direction Indicators Adjusting the Headlights With the ignition switch at position I, press the relevant side of the direction indicator switch, the 2 indicator lamps on that side of the machine will flash. Using the top screws shown in Figure 21, adjust the headlights per local standards.
Notes: 11
Notes: 12
Notes: 13
Declaration of Incorporation The Toro Company, 8111 Lyndale Ave. South, Bloomington, MN, USA declares that the following unit(s) conform(s) to the directives listed, when installed in accordance with the accompanying instructions onto certain Toro models as indicated on the relevant Declarations of Conformity. Model No. 02917 Serial No.
International Distributor List Distributor: Country: Phone Number: Distributor: Phone Number: 57 1 236 4079 Colombia Japan 81 3 3252 2285 Czech Republic 420 255 704 220 420 255 704 Slovakia 220 Argentina 54 11 4 821 9999 Russia 7 495 411 61 20 Ecuador 593 4 239 6970 Finland 358 987 00733 Agrolanc Kft Balama Prima Engineering Equip. B-Ray Corporation Hungary Hong Kong Korea 36 27 539 640 852 2155 2163 82 32 551 2076 Maquiver S.A. Maruyama Mfg. Co. Inc. Mountfield a.s.
Toro General Commercial Product Warranty A Two-Year Limited Warranty Conditions and Products Covered The Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them, jointly warrant your Toro Commercial product (“Product”) to be free from defects in materials or workmanship for two years or 1500 operational hours*, whichever occurs first. This warranty is applicable to all products with the exception of Aerators (refer to separate warranty statements for these products).