Operator's Manual
Troubleshooting
UsingtheStandardControlModule(SCM)
TheStandardControlModuleisapottedelectronicdeviceproducedinaone-size-ts-allconguration.The
moduleusessolidstateandmechanicalcomponentstomonitorandcontrolstandardelectricalfeatures
requiredforsafeproductoperation.
Themodulemonitorsinputsincludingneutral,parkingbrake,PTO,start,backlap,andhightemperature.The
moduleenergizesoutputsincludingPTO,Starter,andETR(energizetorun)solenoid.
Themoduleisdividedintoinputsandoutputs.InputsandoutputsareidentiedbygreenLEDindicators
mountedontheprintedcircuitboard.
Thestartcircuitinputisenergizedby12VDC.Allotherinputsareenergizedwhenthecircuitisclosedto
ground.EachinputhasaLEDthatisilluminatedwhenthespeciccircuitisenergized.UsetheinputLEDsfor
switchandinputcircuittroubleshooting.
Outputcircuitsareenergizedbyanappropriatesetofinputconditions.The3outputsincludePTO,ETR,and
START .OutputLEDsmonitorrelayconditionindicatingthepresenceofvoltageat1of3specicoutputterminals.
Outputcircuitsdonotdetermineoutputdeviceintegrity,soelectricaltroubleshootingincludesoutputLED
inspectionandconventionaldeviceandwireharnessintegritytesting.Measurethedisconnectedcomponent
impedance,theimpedancethroughwireharness(disconnectatSCM),orbytemporarily”testenergizing”
thespeciccomponent.
TheSCMdoesnotconnecttoanexternalcomputerorhandhelddevice,cannotbere-programmed,anddoes
notrecordintermittentfaulttroubleshootingdata.
ThedecalontheSCMonlyincludessymbols.ThreeLEDoutputsymbolsareshownintheoutputbox.Allother
LEDsareinputs.Thechartbelowidentiesthesymbols.
g190826
Figure90
1.Inputs4.Inseat7.Neutral10.ETR
2.Backlap
5.PTOswitch8.PTO
11.Power
3.Hightemperature
6.Parkingbrakeoff9.Start12.Outputs
HerearethelogicaltroubleshootingstepsfortheSCMdevice.
1.Determinetheoutputfaultyouaretryingtoresolve(PTO,START,orETR).
2.MovethekeyswitchtotheONpositionandensurethattheredpowerLEDisilluminated.
3.MovealltheinputswitchestoensurethatallLEDschangestate.
4.Positiontheinputdevicesattheappropriatepositiontoachievetheappropriateoutput.Usethefollowing
logiccharttodeterminetheappropriateinputcondition.
5.IfthespecicoutputLEDisilluminatedwithouttheappropriateoutputfunction,checktheoutputharness,
connections,andcomponent.Repairasneeded.
6.IfthespecicoutputLEDisnotilluminated,checkbothfuses.
7.IfthespecicoutputLEDisnotilluminatedandtheinputsareintheappropriatecondition,installa
newSCManddetermineifthefaultdisappears.
63