Operator's Manual
g008913
Figure61
1.Fuelinjectors
2.MovethethrottletotheFASTposition.
3.TurnthekeyinthekeyswitchtotheSTART
positionandwatchthefuelowaroundthe
connector.TurnthekeytotheOFFposition
whenyouseeasolidow.
4.Tightenthepipeconnectorsecurely.
5.Repeatthisprocedureontheremainingnozzles.
ElectricalSystem
Maintenance
ElectricalSystemSafety
•Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
•Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.Wearprotectiveclothinganduseinsulated
tools.
ServicingtheBattery
ServiceInterval:Every25hours—Checkthe
electrolytelevel.(Ifmachineisin
storage,checkevery30days.)
Thebatteryelectrolytelevelmustbeproperly
maintainedandthetopofthebatterykeptclean.Ifthe
machineisstoredinalocationwheretemperatures
areextremelyhigh,thebatterywillrundownmore
rapidlythanifthemachineisstoredinalocation
wheretemperaturesarecool.
DANGER
Batteryelectrolytecontainssulfuricacid
whichisadeadlypoisonandcausessevere
burns.
•Donotdrinkelectrolyteandavoidcontact
withskin,eyesorclothing.Wearsafety
glassestoshieldyoureyesandrubber
glovestoprotectyourhands.
•Fillthebatterywherecleanwaterisalways
availableforushingtheskin.
•Chargethebatteryinawell-ventilated
placesothatthegassesproducedwhile
chargingcandissipate.
•Sincethegasesareexplosive,keepopen
amesandelectricalsparksawayfromthe
battery;donotsmoke.
•Nauseamayresultifthegasesareinhaled.
•Unplugthechargerfromtheelectrical
outletbeforeconnectingtoor
disconnectingthechargerleads
fromthebatteryposts.
Maintainthecelllevelwithdistilledordemineralized
water.Donotllthecellsabovethebottomofthesplit
41