Operator's Manual

g341294
Figure73
1.Cap
2.Fillerneck(hydraulic-uidreservoir)
3.Dipstick
6.Installthedipstickandcaptothereservoir,start
theengine,anduseallthehydrauliccontrols
todistributethehydraulicuidthroughoutthe
system.
7.Checkforleaks;thenshutofftheengine.
8.Checktheuidlevel,andaddenoughhydraulic
uidtoraisetheleveltoFULLmarkonthe
dipstick;refertoCheckingtheLevelofthe
HydraulicFluid(page47).
Important:Donotoverllthehydraulic
reservoir.
ReplacingtheHydraulic
Filter
ServiceInterval:Every1,000hours—Ifyou
areusingtherecommended
hydraulicuid,replacethe
hydrauliclter.
Every800hours—Ifyouarenotusingthe
recommendedhydraulicuidorhaveever
lledthereservoirwithanalternativeuid,
replacethehydrauliclter.
UseagenuineT ororeplacementlter(PartNo.
54-0110).
Important:Usinganyotherltermayvoidthe
warrantyonsomecomponents.
1.Parkthemachineonalevelsurface,lowerthe
cuttingunits,engagetheparkingbrake,shutoff
theengine,andremovethekey.
2.Pinchoffthehosetotheltermountingplate.
3.Cleanaroundtheltermountingarea.
4.Placeadrainpanunderthelter(Figure72)
andremovethelter.
5.Lubricatethenewltergasketandllthelter
withhydraulicuid.
6.Ensurethattheltermountingareaisclean,
screwthelteronuntilthegasketcontactsthe
mountingplate,andthentightenthelter1/2
turn.
7.Releasethehosetotheltermountingplate.
8.Starttheengineandletitrunforabout2minutes
topurgetheairfromthesystem.
9.Shutofftheengineandcheckforleaks.
10.Checktheuidlevel,andaddenoughhydraulic
uidtoraisetheleveltoFULLmarkonthe
dipstick;refertoCheckingtheLevelofthe
HydraulicFluid(page47).
49