Service Manual

Rev. E
Reelmaster 5200-D/5400-D Hydraulic SystemPage 4 - 85
2. Apply Permabond LH150 or equivalent to the
threads of the hydraulic straight fitting (suction). Secure
fitting to the suction strainer.
3. Apply Permabond LH150 or equivalent to the
threads of the suction strainer.
4. Using a wrench, turn strainer into port at least 1-1/2
to 2 full turns beyond finger tight.
5. Apply an anti-seize compound to three cap screws
that secure the reservoir to the frame. Install and torque
screws30to60in--lb(3.4to6.8N--m).
6. Fill reservoir with hydraulic fluid (see Change Hy-
draulic Fluid).
Hydraulic