Service Manual

Reelmaster 5200-D/5400-D Page 5 - 9 Electrical Systems (Rev. D)
Cutting Unit Operating Problems (Cont.)
None of the cutting units operate in either direction.
Units are able to raise and lower.
The seat sensor actuator is lifting off the seat switch.
The seat sensor or circuit wiring is faulty.
The enable/disable switch or circuit wiring is faulty.
The front reels down sensor or circuit wiring is faulty.
Ground circuit wiring to solenoids may be open.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The rear cutting units do not operate in either direction.
Units are able to raise and lower.
Solenoid S2 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
None of the cutting units will lower. Lower/mow switch on joystick or circuit wiring is faulty.
Solenoid S6 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
None of the cutting units will raise. Raise switch on joystick or circuit wiring is faulty.
Solenoid S7 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Left and right front cutting units will not raise or lower,
but the other cutting units will raise and lower.
Solenoid S3 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The center front cutting unit will not raise or lower, but
the other cutting units will raise and lower.
Solenoid S4 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The rear cutting units will not raise or lower, but the
other cutting units will raise and lower.
Solenoid S5 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The front cutting units do not backlap, but run in the
forward direction instead.
Solenoid S8 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The front cutting units do not backlap, but all cutting
units run in the forward direction.
The front backlap switch or circuit wiring is faulty.
The rear cutting units do not backlap, but run in the
forward direction instead.
Solenoid S9 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The rear cutting units do not backlap, but all cutting
units run in the forward direction.
The rear backlap switch or circuit wiring is faulty.
Electrical
System