Service Manual

Reelmaster 5200-D/5400-DPage 5 - 14Electrical Systems (Rev. D)
Electrical System Quick Check
Battery Test (Open Circuit Test)
Use a multimeter to measure the voltage between the
battery terminals.
Set multimeter to the DC volts setting. The battery
should be at a temperature of 60 to 100F (16 to 38C).
The ignition key should be off and all accessories turned
off. Connect the positive (+) meter lead to the positive
battery post and the negative (-) meter lead the the neg-
ative battery post.
NOTE: This test provides a relative condition of the bat-
tery. Load testing of the battery will provide additional
and more accurate information.
Voltage Measured
Battery Charge Level
12.68 V (or higher) Fully charged (100%)
12.45 V 75% charged
12.24 V 50% charged
12.06 V 25% charged
11.89 V 0% charged