Service Manual

Fault
Number
Fault Title
Controller
Affected
Fault Condition/
Circuit
Description
Additional Notes
Service Actions
(Repair or replace any
worn or damaged parts)
104
Over Current
Disable CRM 5
Cutting Reel
Motor Controller
Cutting reel motor 5
has detected excessive
current draw and has
been disabled.
Check the InfoCenter for fault
69 (Speed StallCRM 5) or
fault 74 (High Temp Warning
CRM 5), as an overheated
cutting reel motor or a cutting
reel motor stall could be a
contributing factor to a fault 104.
1) Swap cutting reel motors
between cutting units. Replace
the motor if the fault moves to
the new position.
2) Inspect main harness
connectors P44 and P45 at
cutting reel motor 5 for damage,
corrosion, debris, and proper
alignment of the pins inside the
connectors.
3) Test connectors P44 and P45
for 48V with the engine off and
the key in the ON position.
4) Test the power and ground
wiring resistance in main
harness connectors P44 and
P45.
111
Internal Regulator
Overvolt
Motor/Generator
Motor/Generator
Controller
Excessive voltage
occurred at the
motor/generator’s 15
Vdc internal regulator,
and disabled the
motor/generator.
This fault can only be triggered
by a failure of the internal
motor/generator controller.
Such a failure would allow
voltage levels beyond
engineering specifications to
exist in the 48 Vdc circuitry.
Replace the motor/generator
controller.
Reelmaster 5010-H Diagnostic Fault Code Quick Reference Table Page 33 of 38