Service Manual

AngleIndicatorandMagneticMount
AngleIndicator:ToroPartNo.131–6828
MagneticMount:ToroPartNo.131–6829
Becausethetopgrindangleonbedknives
iscriticalforedgeretention,andtherefore
after-cutappearance,T orohasdevelopthese
servicetoolsforaccuratelymeasuringthetop
grindangleonallbedknives.
Sincetherecanbevariationsinthemounting
surfaceofthebedbar,itisnecessarytogrind
thebedknifeafterinstallingittothebedbar.
1.Placetheangleindicatoronthebottomside
ofthebedknifewiththedigitaldisplayfacing
youasshown.
2.PresstheAltZerobuttonontheangle
indicator.
g223327
Figure323
1.Bedknife
3.Bedbar
2.AngleIndicator
3.Removetheangleindicatorandplacethe
magneticmountontheedgeofthebedknifeso
thatthefaceofthemagnetisatagainstthe
topangleofthebedknife.
4.Placetheangleindicatoronthemountwith
thedigitaldisplayfacingyouasshown.The
angledisplayedontheindicatoristhecurrent
bedknifetopangle.
g223326
Figure324
1.Angleindicatorsurface
4.Bedbar
2.Magneticmount5.Angleindicator
3.Bedknife
Reelmaster
®
5410/5510/5610Series
Page9–9
CuttingUnit:SpecialTools
15216SLRevD