Operator's Manual

6.Engagetheparkingbrake.
7.SetthethrottletothelowIDLEposition.
PerformingaParkedorRecoveryRegeneration
CAUTION
Theexhausttemperatureishot(approximately600°C
(1,112°F)duringDPFregeneration.Hotexhaustgas
canharmyouorotherpeople.
Neveroperatetheengineinanenclosedarea.
Makesurethattherearenoammablematerials
aroundtheexhaustsystem.
Nevertouchahotexhaustsystemcomponent.
Neverstandnearoraroundtheexhaustpipeofthe
machine.
Important:Thecomputerofthemachinecancels
DPFregenerationifyouincreasetheenginespeed
fromlowidleorreleasetheparkingbrake.
1.AccesstheDPFRegenerationmenu,pressthecenter
buttontoscrolldowntoeitherthePARKEDREGEN
STARToptionortheRECOVERYREGENSTARToption
(Figure83),andpresstherightbuttontoselectthe
starttheregeneration(Figure83).
g224402
g224629
Figure83
2.AttheVERIFYFUELLEVELscreen,verifythatyouhave
1/4tankoffuelifyouareperformingtheparked
regenerationor1/2tankoffuelifyouareperforming
therecoveryregeneration,andpresstherightbutton
tocontinue(Figure84).
g224414
g227678
Figure84
3.AttheDPFchecklistscreen,verifythattheparking
brakeisengagedandthattheenginespeedissetto
lowidle(Figure85).
g224407
g227679
Figure85
4.AttheINITIATEDPFREGENscreen,presstheright
buttontocontinue(Figure86).
44