Operator's Manual
6.Engagetheparkingbrake.
7.SetthethrottletothelowIDLEposition.
PerformingaParkedRegeneration
Note:Forinstructionsonunlockingprotectedmenus,
refertoAccessingProtectedMenus(page24).
1.Accesstheprotectedmenuandunlockthe
protectedsettingssubmenu(Figure41);referto
AccessingProtectedMenus(page24).
g028523
Figure41
2.NavigatetotheMAINMENU,pressthecenter
buttontoscrolldowntotheSERVICEMENU,and
presstherightbuttontoselecttheSERVICE
option(Figure42).
Note:TheInfoCentershoulddisplaythePIN
indicatorintheupperrightcornerofthedisplay.
g212371
Figure42
3.IntheSERVICEMENU,pressthemiddlebutton
untiltheDPFREGENERATIONoptionsdisplays,
andpresstherightbuttontoselecttheDPF
REGENERATIONoption(Figure43).
g212138
Figure43
4.Whenthe“InitiateDPFRegen.Areyousure?”
messagedisplays,pressthecenterbutton
(Figure44).
g212125
Figure44
5.Ifthecoolanttemperatureisbelow60°C(140°F)
the“Insure
isrunningandabove60C/140F”
messagedisplays.(Figure45).
Observethetemperatureinthedisplay,andrun
themachineatfullthrottleuntilthetemperature
reaches60°C(140°F),thenpressthecenter
button.
Note:Ifthecoolanttemperatureisabove60°C
(140°F)thisscreenisskipped.
37