Operator's Manual

7.Starttheengineanduseallofthehydraulic
controlstodistributehydraulicuidthroughout
thesystem.Also,checkforleaks.
8.Shutofftheengine.
9.Checkthelevelofthehydraulicuidandadd
enoughtoraiseleveltotheFULLmarkonthe
dipstick.
Important:Donotoverllthehydraulic
system.
ReplacingtheHydraulic
Filters
ServiceInterval:Every800hours(Ormoreoftenif
theservice-intervalindicatorisin
theredzone).
Thehydraulicsystemisequippedwitha
service-intervalindicator(Figure89).Withtheengine
runningatoperatingtemperature,viewtheindicator,it
shouldbeinthegreenzone.Whentheindicatorisin
theredzone,changethehydrauliclters.
g004132
Figure89
1.Hydraulic-lter-restrictionindicator
Important:Useofanyotherltersmayvoidthe
warrantyonsomecomponents.
1.Positionthemachineonalevelsurface,lower
thecuttingunits,shutofftheengine,engage
theparkingbrake,andremovethekeyfromthe
ignitionswitch.
2.Cleantheareaaroundthelter-mountingarea
andplaceadrainpanunderthelter(Figure90)
and(Figure91).
g021271
1
g021271
Figure90
1.Hydrauliclter
61