Service Manual

Reelmaster 5410/5510/5610 (Tier 4) Diagnostic Fault Code Quick Reference Table Page 4 of 4
Fault
Number
Fault Title
Controller
Affected
Fault Condition/
Circuit
Description
Additional Notes
Service Actions
(Repair or replace any
worn or damaged parts)
53
SV1 Out
Master TEC
This fault is reported
when the output
current exceeds 5
amps from the TEC to
the SV1 hydraulic
lift/lower solenoid.
If you replace the TEC, use
Toro DIAG to save the machine
timers and counters file.
1) Measure the resistance of the
SV1 coil.
2) Test the wiring harness for SV1
at OUT 11.
3) Replace the TEC controller.
54
SV2 Out
Master TEC
This fault is reported
when the output
current exceeds 5
amps from the TEC to
the SV2 hydraulic
lift/lower solenoid.
If you replace the TEC, use
Toro DIAG to save the machine
timers and counters file.
1) Measure the resistance of the
SV2 coil.
2) Test the wiring harness for SV2
at OUT 12.
3) Replace the TEC controller.
55
SV3 Out
Master TEC
This fault is reported
when the output
current exceeds 5
amps from the TEC to
the SV3 hydraulic
lift/lower solenoid.
If you replace the TEC, use
Toro DIAG to save the machine
timers and counters file.
1) Measure the resistance of the
SV3 coil.
2) Test the wiring harness for SV3
at OUT 13.
3) Replace the TEC controller.
56
SVRV Out
Master TEC
This fault is reported
when the output
current exceeds 5
amps from the TEC to
the SVRV (SV4)
hydraulic lift/lower
solenoid.
If you replace the TEC, use
Toro DIAG to save the machine
timers and counters file.
1) Measure the resistance of the
SVRV coil.
2) Test the wiring harness for
SVRV at OUT 14.
3) Replace the TEC controller.
57
MSV1 Out
Master TEC
This fault is reported
when the output
current exceeds 5
amps from the TEC to
the MSV1 hydraulic
solenoid.
1) Measure the resistance of the
MSV1 coil.
2) Test the wiring harness for
MSV1 at OUT 5.
3) Replace the TEC controller.
58
MSV2 Out
Master TEC
This fault is reported
when the output
current exceeds 5
amps from the TEC to
the MSV2 hydraulic
solenoid.
If you replace the TEC, use
Toro DIAG to save the machine
timers and counters file.
1) Measure the resistance of the
MSV2 coil.
2) Test the wiring harness for
MSV2 at OUT 6.
3) Replace the TEC controller.