Operator's Manual
BeltMaintenance
ServicingtheAlternator
Belt
ServiceInterval:Aftertherst10hours
Every100hours
Checktheconditionandtensionofthebelt(Figure
85)afterevery100operatinghours.
1.Propertensionwillallow10mm(3/8inch)
deectionwhenaforceof44N(10lb)isapplied
onthebeltmidwaybetweenthepulleys.
2.Ifthedeectionisnot10mm(3/8inch),loosen
thealternatormountingbolts(Figure85).
Increaseordecreasethealternatorbelttension
andtightenthebolts.Checkthedeectionofthe
beltagaintoensurethatthetensioniscorrect.
g020537
Figure85
1.Mountingbolt2.Alternator
HydraulicSystem
Maintenance
ChangingtheHydraulic
Fluid
Changehydraulicuidafterevery800operating
hours,innormalconditions.Ifuidbecomes
contaminated,contactyourlocalT orodistributor
becausethesystemmustbeushed.Contaminated
uidlooksmilkyorblackwhencomparedtocleanoil.
1.Stoptheengineandraisethehood.
2.Placealargedrainpanunderthettingsecured
tothebottomofthehydraulicuidreservoir
(Figure86).
g004139
Figure86
1.Hose
3.Disconnectthehosefromthebottomofthe
ttingandletthehydraulicuidowintothe
drainpan.
4.Installthehosewhenhydraulicuidstops
draining.
5.Fillthereservoirwithapproximately30liters(8
U.S.gallons)ofhydraulicuid;refertoChecking
theHydraulicFluid.
Important:Useonlyhydraulicuids
specied.Otheruidscouldcausesystem
damage.
6.Installthereservoircap.
7.Starttheengineanduseallofthehydraulic
controlstodistributehydraulicuidthroughout
thesystem.Alsocheckforleaks.
8.Stoptheengine.
55