Operator's Manual
BleedingAirfromtheInjectors
Note:Thisprocedureshouldbeusedonlyifthefuel
systemhasbeenpurgedofairthroughnormalpriming
proceduresandtheenginewillnotstart.
1.LoosenthepipeconnectiontotheNo.1injector
nozzleandholderassemblyattheinjectionpump
(
Figure60).
Figure60
1.No.1injectornozzle
2.MovethethrottletotheFastposition.
3.TurnthekeyintheignitionswitchtotheStart
positionandwatchthefuelowaroundthe
connector.TurnthekeytotheOffpositionwhen
solidowisobserved.
4.Tightenthepipeconnectorsecurely.
5.Repeattheprocedureontheremainingnozzles.
ElectricalSystem
Maintenance
ChargingandConnectingthe
Battery
WARNING
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandleadcompounds,
chemicalsknowntotheStateofCalifornia
tocausecancerandreproductiveharm.
Washhandsafterhandling.
1.Unlatchandraisetheoperator'sconsolepanel
(Figure61).
Figure61
1.Operator'sconsolepanel
2.Latch
DANGER
Batteryelectrolytecontainssulfuricacidwhich
isadeadlypoisonandcausessevereburns.
•Donotdrinkelectrolyteandavoidcontact
withskin,eyesorclothing.Wearsafety
glassestoshieldyoureyesandrubbergloves
toprotectyourhands.
•Fillthebatterywherecleanwaterisalways
availableforushingtheskin.
43