Service Manual

Reelmaster 7000Hydraulic System Page 4 -- 66
Gear Pump P4 Flow (Cooling Fan Circuit) Test (Using Tester with Pressure Gauges and
Flow Meter)
Working Pressure
Low Pressure
Return or Suction
Flow
.071
VALVE
PSI
BYPASS
P1
.091
5000
.56.56
P4
1.031.03
P2P3
PSI
5000
.071
PISTON PUMP
GEAR
PUMP
2.48
ENGINE SPEED
2850/1550
TO FAN CIRCUIT
TO STEERING AND LIFT CIRCUITS
FROM RESERVOIR FROM FILTRATION MANIFOLD
TESTER
TO MOW CONTROL
MANIFOLD (P1 PORT)
TO MOW CONTROL
MANIFOLD (P2 PORT)