Service Manual

Reelmaster 7000Hydraulic System Page 4 -- 68
Adjustments
Adjust Control Manifold Relief Valves
Several of the hydraulic control manifolds on your Reel-
master include adjustable relief v alves. The following
procedure can be used to adjust theserelief valves. Re-
fer to the Testing section of this chapter for information
on testing relief pressure.
NOTE: Do not remove relief valve from the hydraulic
manifold for adjustment.
1. Locate relief valve on control manifold.
2. Remove cap on relief valve with an allen w rench.
3. To increase pressure setting, turn the adjustment
socket on the valve in a clockwise direction. A 1/8 turn
on the socket will make a measurable change in relief
pressure.
4. To decrease pressure setting, turn the adjustment
socket on the valve in a counterclockwise direction. A
1/8 turn on the socket will make a measurable change
in relief pressure.
5. Install and tighten cap on relief valve.
6. Recheck relief pressure and readjust as needed.
Figure 49
1. Relief valve cap 2. Adjustment socket
1
2