Service Manual

Table Of Contents
Reelmaster 7000−DHydraulic System Page 5 − 42
10.Record reading on pressure gauge. Charge pres-
sure (under load) should not drop more than 20% when
compared to charge pressure (without load) recorded in
step 8.
If specifications are not met, perform Piston (traction)
Pump Flow Test as outlined in this chapter.
11.Release traction pedal, set parking brake, move
throttle to low speed and turn the engine off.
12.Remove pressure gauge and tee fitting when testing
is completed. Install charge circuit hose and check for
leaks.