Service Manual

Table Of Contents
Reelmaster 7000−DHydraulic System Page 5 − 68
12.While watching tester pressure gauge, slowly close
flow control valve on tester until a pressure of 2000 PSI
(138 bar) is obtained.
NOTE: Use a graduated container (special tool
TOR4077) to measure case drain leakage.
13.Measure oil flow from the disconnected case drain
line for fifteen (15) seconds, then move the reel enable/
disable switch to DISABLE, open the tester flow control
valve and stop the engine. Record test results.
TEST RESULTS: Case drain leakage should be less
than 23 ounces (672 ml) of hydraulic fluid in fifteen
(15) seconds (0.7 GPM / 2.7 LPM).
14.If case drain flow is more than 23 ounces (672 ml)
in fifteen (15) seconds, the reel motor is worn or dam-
aged and should be repaired or replaced.
15.Disconnect tester from motor and hose. Reconnect
hose to the cutting unit motor. Remove cap from bulk-
head fitting and reconnect case drain hose.
16.Repeat test for additional reel motors if required.
17.When finished, use the InfoCenter display to return