Service Manual

Table Of Contents
Reelmaster 7000−DHydraulic System Page 5 − 76
Cooling Fan Circuit − Pressure Test
High Pressure
Low Pressure
Return or Suction
Flow
PRESSURE
GAUGE
OIL COOLER
0.51 CID
1450 psi
1.6 CID
1050 psi
6.6 GPM
12.1 GPM
P1
G1
M3M4
T
PRV
S1
CV
FD
P2
P1
ST
L
M1
PT
T2
50/50 SPLIT
FAN CONTROL
MANIFOLD
6.6 GPM
12.1 GPM
RETURN FILTER
P2
G2
G2
G1
3.3 GPM
0.56
CID
0.56
CID
1.03
CID
1.03
CID
STEERING
CYLINDER
FAN
STEERING
UNIT
110 psi
3000 psi
.040
3000 psi
.040
110 psi
MV2MV1
SP1
M1
1450 psi
1.6 CID
1450 psi
1.6 CID
1450 psi
1.6 CID
1450 psi
1.6 CID
CV1
LC1
RV1
OR2OR1
STRAINER
BREATHER
REEL
EXTEND
#4 #1 #5 #2 #3
MOTORS
FRONT REAR
MOW CONTROL
M2
M2
50 psi
6.1
CIR
P2P3P4P5
MOTOR
TO TURN RIGHT
T1
RV2
SP2
LC2
CV2
MANIFOLD
E
GEAR
PUMP
TO LIFT
MANIFOLD
TO CHARGE
CIRCUIT