Service Manual

Table Of Contents
Reelmaster 7000−D Page 6 − 13 Electrical System
Faults Screen
The faults screen (Fig. 13) will list all machine electrical
faults that have occurred since the faults were last
cleared from the InfoCenter. The faults will be identified
by a number code and when the fault occurred. See
Table 3: Fault Codes in the Troubleshooting section of
this chapter for a listing of the possible fault codes for the
Reelmaster 7000−D.
If a machine fault occurs during operation, the InfoCent-
er fault indicator will blink to notify the operator, and ma-
chine functionality may be affected due to the fault. To
regain full machine functionality:
A. Disengage the cutting units
B. Turn the ignition switch OFF and allow all ma-
chine functions to stop
C. Allow the machine to remain OFF for at least one
(1) minute
D. Restart the engine and check machine operation
E. If a fault continues, further system evaluation and
possible component repair or replacement will be
necessary
To view a description of a fault that has occurred since
the faults were last cleared from the InfoCenter, press
the Down button (as indicated by the
at the bottom of
the screen) to highlight the desired fault, then press the
Left/Right button (as indicated by the
).
To return to the previous screen, press the Menu/Back
button (as indicated by the
at the bottom of the
screen).
NOTE: Yanmar Diesel Engines − If an engine fault oc-
curs during machine operation, the fault indicator will il-
luminate and the fault will be displayed on the InfoCenter
to notify the operator (Fig. 14). The engine fault will con-
tinue to appear until the offending condition is corrected.
Once the offending condition has been corrected, the
engine fault will be retained in the engine electronic con-
trol unit (ECU) and can only be viewed using the engine
diagnostic tool. Engine faults are not stored in the Toro
Electronic Controller (TEC) so engine fault history can-
not be viewed using the InfoCenter faults screen.
Clear System Faults (PIN required) If the correct pass-
code (PIN) has been entered (see Settings Screen −
Protected Menus in this chapter) the InfoCenter fault log
can be cleared by selecting Clear System Faults. The
cleared faults will be removed from the InfoCenter list
but will be retained in the TEC memory. Contact your
Toro Distributor to view faults stored in the TEC memory.
1. Fault code (highlighted)
2. Down button
3. Left/Right button
4. Fault description
Figure 13
FAULT #12
Timeout
CAN
Faults
Cleared @
−5.49 Ago
1
4
2
3
FAULTS SCREEN
FAULT DESCRIPTION
1. Engine fault (Yanmar Diesel engine)
Figure 14
ENGINE FAULT (YANMAR DIESEL ENGINE)
Check Engine
SPN: 110
FMI: 3 Occ:1
See Service Manual
Electrical
System