Service Manual

Table Of Contents
Reelmaster 7000−DPage 6 − 26Electrical System
Starting Problems
NOTE: Check InfoCenter Display for possible operator
advisories or faults whenever diagnosing machine elec-
trical problems.
Problem
Possible Causes
No electrical power to machine (including gauges). Battery is discharged.
Battery cables are loose or corroded.
Ground connection on machine is loose or corroded.
Fuse F−D1 (2 amp) is faulty (open).
The ignition switch or circuit wiring is faulty.
Starter solenoid clicks, but starter will not crank.
NOTE: If the solenoid clicks, the problem is not in the in-
terlock circuit.
Battery is discharged.
Battery cables are loose or corroded.
Ground connection on machine is loose or corroded.
Wiring at the starter is faulty.
Starter solenoid is faulty.
Starter is faulty.
Nothing happens when start attempt is made but
Operator Advisory is displayed on InfoCenter (see
Operator Advisory list in this section).
The traction pedal is not in neutral position.
Operator seat is unoccupied OR the parking brake is
not applied.
The reel enable/disable switch is ENABLED.
The joystick is in the raise or lower position
The traction neutral switch or circuit wiring is faulty.
Seat switch or circuit wiring is faulty.
Parking brake switch or circuit wiring is faulty.
Reel enable/disable switch or circuit wiring is faulty.
Joystick switches or circuit wiring is faulty.
Engine or fuel system is malfunctioning (see Engine
Service Manual).
Nothing happens when start attempt is made.
InfoCenter display operates with the ignition switch in
the ON position. No Operator Advisory displayed on
InfoCenter.
TEC fuses F−A1 (7.5 amp) protecting the fuel pump
and start relay circuits is faulty.
Ignition switch or circuit wiring is faulty.
The fusible link harness at the engine starter motor is
faulty.
Start relay or circuit wiring is faulty.
Starter solenoid or starter motor is faulty.