Reelmaster 7000−DPage 6 − 32Electrical System
Check Operation of Interlock Switches
CAUTION
Do not disconnect safety switches. They are for
the operator’s protection. Check the operation of
the interlock switches daily for proper operation.
Replace any malfunctioning switches before op-
erating the machine.
Interlock switch operation is described in the Traction
Unit Operator’s Manual. Your Reelmaster is equipped
with an Toro Electronic Controller (TEC) which monitors
interlock switch operation. Testing of individual interlock
switches is included in the Component Testing section
of this Chapter.
NOTE: Use the InfoCenter Display (see InfoCenter
Display in this chapter) to test Toro Electronic Controller
inputs and outputs before further troubleshooting of an
electrical problem on your Groundsmaster.