Service Manual

Table Of Contents
Reelmaster 7000−DPage 6 − 38Electrical System
Toro Electronic Controllers (TEC)
Reelmaster 7000−D machines use a Toro Electronic
Controller (TEC) to control electrical system operation.
The controller contains a microcontroller that monitors
the condition of various switches and senders (inputs).
The controller then directs electrical power to control ap-
propriate machine functions (outputs) based on the in-
put conditions. The controller is attached to a bracket
under the operator seat (Fig. 31).
Logic power is provided to the controllers as long as the
battery cables are connected to the battery. A 2 amp
fuse (F−D1) provides circuit protection for the logic pow-
er to the controller.
The electrical power for controller outputs is provided
through three (3) connector terminals (PWR 2, PWR 3
and PWR 4). Three (3) 7.5 amp fuses (F−A1, F−B1, and
F−C1) provide circuit protection for the controller out-
puts.
The TEC monitors the states of the following compo-
nents as inputs:
Input Number
Description
IN 1 Parking Brake Switch OFF
IN 2 Cutting Unit Position Switch
IN 3 Neutral Switch
IN 4 Seat Switch
IN 5 HIGH/LOW (transport/mow) Switch
IN 6 Joystick Raise Switch
IN 7 Joystick Lower Switch
IN 8 Reel Enable/Disable Switch
IN 9
Engine Speed Switch − Increase
(Yanmar diesel engines)
− OR −
Engine Oil Pressure
(Kubota diesel engines)
IN 10 Front Backlap
IN 11 Rear Backlap
IN 12
Engine Speed Switch − Decrease
(Yanmar diesel engines)
− OR −
Alternator
(Kubota diesel engines)
ANALOG IN 5 Hydraulic Oil Temperature Sender
ANALOG IN 6
Engine Temperature Sender
(Kubota diesel engines)
Figure 31
1
1. Toro Electronic Controller
The TEC controls electrical output to the following out-
puts:
Output
Number
Description
OUT 1
Engine ECU (Yanmar engine)
− OR −
Start Relay (Kubota engine)
OUT 2
Fuel Pump and
Engine ECU (Yanmar engine)
− OR −
Fuel Stop Solenoid Hold Coil
(Kubota engine)
OUT 3 Fan Direction Solenoid Valve (S1)
OUT 4
Front Cutting Units
Lift and Lower Solenoid Valve (S4)
OUT 5
Front Cutting Units Engage
Proportional Valve (SP1)
OUT 6
Rear Cutting Units Engage
Proportional Valve (SP2)
OUT 7 Fan Speed Proportional Valve (PRV)
OUT 8 Not Used
OUT 9
Rear Cutting Units
Lift and Lower Solenoid Valve (S5)
OUT 10
Cutting Units
Lift or Lower (direction)
Solenoid Valve (S2)
OUT 11 Glow Relay (Kubota diesel engines)
OUT 12 Not Used
OUT 13
Cutting Units Lift and Lower (enable)
Solenoid Valves (S1 and S3)
OUT 14
HIGH/LOW (transport/mow)
Range Solenoid Valve