Service Manual

Table Of Contents
Reelmaster 7000−D Page 6 − 67 Electrical System
Hydraulic Solenoid Valve Coils
A solenoid valve coil on a hydraulic control manifold can
be replaced without opening the hydraulic system.
Removal (Fig. 72)
1. Park machine on a level surface, lower cutting units,
stop engine and engage parking brake. Remove key
from ignition switch.
2. Locate solenoid valve coil that is to be removed (see
Chapter 5 − Hydraulic System in this manual for assis-
tance in locating specific solenoid valves).
3. Disconnect wire harness electrical connector from
the coil that is to be removed. Note orientation of electri-
cal connector on coil for assembly purposes.
4. Remove nut that secures coil to hydraulic valve.
5. Slide solenoid coil from valve.
6. Clean any corrosion or dirt from valve stem.
Installation (Fig. 72)
1. Slide solenoid coil onto the hydraulic valve. Position
coil so that connector is properly orientated.
2. Install nut onto valve and torque nut 60 in−lb (6.8
N−m) (do not over tighten).
3. Connect machine wire harness connector to the so-
lenoid coil.
1. Control manifold
2. Solenoid valve
3. Solenoid coil
4. Nut
Figure 72
2
4
3
60 in−lb
(6.8 N−m)
1
LIFT MANIFOLD SHOWN
Electrical
System